• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:刘咏梅,阮丹,王建.近红外光谱法快速分析注射用盐酸头孢甲肟及其水分的含量[J].中国现代应用药学,2013,30(1):61-65.
LIU Yongmei,RUAN Dan,WANG Jian.Rapid Determination of Cefmenoxime and Moisture in Cefmenoxime Hydrochloride for Injection by Near-infrared Spectroscopy[J].Chin J Mod Appl Pharm(中国现代应用药学),2013,30(1):61-65.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2880次   下载 3295 本文二维码信息
码上扫一扫!
分享到: 微信 更多
近红外光谱法快速分析注射用盐酸头孢甲肟及其水分的含量
刘咏梅1, 阮丹2, 王建1
1.浙江省食品药品检验研究院,杭州 310004;2.浙江工业大学,杭州 310014
摘要:
目的 建立近红外通用性模型,对注射用盐酸头孢甲肟及其水分进行无损、快速定量分析。方法 以不同企业生产的注射用盐酸头孢甲肟为分析对象,用光纤测定近红外漫反射光谱,并通过聚类分析方法确定校正集和预测集,考察不同预处理方法、谱段的影响,选择建立最佳的注射用盐酸头孢甲肟及其水分的定量模型。结果 注射用盐酸头孢甲肟定量分析模型由36个校正集样品建立校正模型,17个样品用于外部验证,验证集相关系数为96.33%,校正集均方差为1.19%,验证集均方差为1.66%。注射用盐酸头孢甲肟水分定量分析模型由34个样品校正集样品建立校正模型,19个样品用于外部验证,验证集相关系数为96.39%,校正集均方差为0.22%,验证集均方差为0.26%。结论 2个模型结合可以对注射用盐酸头孢甲肟含量和水分进行快速测定,方法简便,结果准确可靠,适合大量重复性样品的分析测定。
关键词:  盐酸头孢甲肟  水分  近红外漫反射光谱  定量分析
DOI:
分类号:
基金项目:
Rapid Determination of Cefmenoxime and Moisture in Cefmenoxime Hydrochloride for Injection by Near-infrared Spectroscopy
LIU Yongmei1, RUAN Dan2, WANG Jian1
1.Zhejiang Institute for Food and Drug Control, Hangzhou 310004, China;2.Zhejiang University of Technology, Hangzhou 310014, China
Abstract:
OBJECTIVE To develop a universal near-infrared reflectance model for rapid and nondestructive determination of cefmenoxime and moisture in cefmenoxime hydrochloride for injection. METHODS Using cluster analysis method, cefmenoxime hydrochloride for injection from different pharmaceutical companies were measured by a fiber optic probe and were divided into calibration and validation groups. Then, the quantitative models were established using partial least square through selection of different wavelength ranges, preprocessing methods. RESULTS For the quantitative model of cefmenoxime content, 36 batches of samples were used as calibration set, and 17 batches as validation set. The root mean square error of calibration was 1.19%, and the root mean square error of validation was 1.66%, and correlation coefficients was 96.33%. For the quantitative model of water content, 34 batches of samples were used as calibration set, and 19 batches as validation set. The root mean square error of calibration was 0.22%, and the root mean square error of validation was 0.26%, and correlation coefficients was 96.39%. CONCLUTION Using this two quantitative models, cefmenoxime hydrochloride for injection can be quickly evaluated. The method is simple and rapid, and can be used in the mobile lab.
Key words:  cefmenoxime hydrochloride  moisture content  near-infrared diffuse reflectance spectroscopy  quantitative determination
扫一扫关注本刊微信