引用本文:阮昊,陈丹丹,金银秀,陈悦.分子排阻色谱法测定注射用头孢哌酮钠舒巴坦钠中的高分子聚合物[J].中国现代应用药学,2013,30(1):79-83.
RUAN Hao,CHEN Dandan,JIN Yinxiu,CHEN Yue.Determination of High Molecular Polymers in Cefoperazone Sodium and Sulbactam Sodium for Injection by Molecular Exclusion Chromatography[J].Chin J Mod Appl Pharm(中国现代应用药学),2013,30(1):79-83.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2678次   下载 2388 本文二维码信息
码上扫一扫!
分享到: 微信 更多
分子排阻色谱法测定注射用头孢哌酮钠舒巴坦钠中的高分子聚合物
阮昊1, 陈丹丹1, 金银秀2, 陈悦1
1.浙江省食品药品检验研究院,杭州 310004;2.台州职业技术学院,浙江 台州 318000
摘要:
目的 建立注射用头孢哌酮钠舒巴坦钠中高分子聚合物的测定方法。方法 采用Sephadex G-10凝胶色谱柱(15.0 mm×300 mm),以pH 7.0的0.05 mol·L-1磷酸盐缓冲液[0.05 mol·L-1磷酸氢二钠溶液-0.05 mol·L-1磷酸二氢钠溶液(61∶39)]为流动相A,以水为流动相B,流速为1.2 mL·min-1,检测波长为254 nm。结果 头孢哌酮高分子聚合物与头孢哌酮药物单体能较好分离,头孢哌酮自身对照的线性范围为5.01~250.71 μg·mL-1(r=0.999 9);在10.13~30.24 mg·mL-1内,供试品溶液浓度与聚合物峰面积呈良好线性关系(r=0.999 9);定量限为0.14 μg;方法精密度良好(RSD=0.50%,n=5);样品测定重复性与重现性好(RSD=0.82%,n=5;RSD=3.4%,n=3)。结论 所建方法操作简便、结果可靠,可用于注射用头孢哌酮钠舒巴坦钠中高分子聚合物的检测。
关键词:  头孢哌酮钠舒巴坦钠  高分子聚合物  分子排阻色谱法
DOI:
分类号:
基金项目:
Determination of High Molecular Polymers in Cefoperazone Sodium and Sulbactam Sodium for Injection by Molecular Exclusion Chromatography
RUAN Hao1, CHEN Dandan1, JIN Yinxiu2, CHEN Yue1
1.Zhejiang Institute for Food and Drug Control, Hangzhou 310004, China;2.Taizhou Vocational and Technical College, Taizhou 318000, China
Abstract:
OBJECTIVE To establish a method for the determination of high molecular polymers in cefoperazone sodium and sulbactam sodium for injection. METHODS Chromatographic analysis was performed on Sephadex G-10 column(15.0 mm×300 mm), 0.05 mol·L-1 phosphate buffer (pH 7.0) as the mobile phase A, and super pure water as the mobile phase B. The flow rate was 1.2 mL·min-1 and the detection wavelength was 254 nm. RESULTS High molecular polymers in cefoperazone was separated completely from cefoperazone. The linear range of cefoperazone was 5.01-250.71 μg·mL-1(r=0.999 9). The linear range of the substances examined was 10.13-30.24 mg·mL-1(r=0.999 9). The limit of quantification was 0.14 μg. The RSD for replicate injections of reference solution was 0.50%(n=5), the repetitiveness and the reproducibility were fine, the RSDs were 0.82%(n=5) and 3.4%(n=3), respectively. CONCLUSION The method is simple, rapid and reliable. It is applicable for the quality control of cefoperazone sodium and sulbactam sodium for injection.
Key words:  cefoperazone sodium and sulbactam sodium  high molecular polymers  molecular exclusion chromatography