• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:陈立,王凌,王少明,庄波阳,陈鼎雄.LC-MS/MS分析有机磷农药中毒[J].中国现代应用药学,2013,30(1):90-95.
CHEN Li,WANG Ling,WANG Shaoming,ZHUANG Boyang,CHEN Dingxiong.Poison Analysis of Organophosphorus Pesticides by LC-MS/MS[J].Chin J Mod Appl Pharm(中国现代应用药学),2013,30(1):90-95.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 2335次   下载 3115 本文二维码信息
码上扫一扫!
分享到: 微信 更多
LC-MS/MS分析有机磷农药中毒
陈立1, 王凌1, 王少明1, 庄波阳2, 陈鼎雄2
1.福建医科大学省立临床医学院/福建省立医院药学部,福州 350001;2.福建省药品检验所,福州 350001
摘要:
目的 建立一种同时检测人血浆中9种有机磷农药的高效液相色谱串联质谱法(LC-MS/MS)。方法 色谱柱为Thermo C18(4.6 mm×250 mm,5 μm),柱温25 ℃,流动相为乙腈-水(含20 mmol·L-1醋酸铵和0.1%甲酸)(85∶15),流速0.3 mL·min-1。血浆样品采用乙腈沉淀蛋白,质谱以正离子方式检测,采用多重反应监测模式(MRM)。结果 9种有机磷农药的线性范围为0.05~10 μg·mL-1,定量下限为0.05 μg·mL-1,检测限在0.1~5 ng·mL-1之间,方法回收率在93.23%~107.5%之间,批内、批间精密度均<10%,稳定性良好。结论 该方法准确灵敏、简单快速,可用于筛查、测定患者体内的有机磷农药,有效辅助临床对中毒患者的诊断和疗效评价。
关键词:  血浆  有机磷  高效液相色谱串联质谱法  检测
DOI:
分类号:
基金项目:
Poison Analysis of Organophosphorus Pesticides by LC-MS/MS
CHEN Li1, WANG Ling1, WANG Shaoming1, ZHUANG Boyang2, CHEN Dingxiong2
1.Department of Pharmacy, Provincial Clinical College of Fujian Medical University/Fujian Provincial Hospital, Fuzhou 350001, China;2.Fujian Provincial Institute for Drug control, Fuzhou 350001, China
Abstract:
OBJECTIVE To establish a liquid chromatography/tandem mass spectrometry method(LC-MS/MS) to simultaneously determine nine organophosphorus pesticides in human plasma. METHODS The analytes were chromatographed on a Thermo C18 (4.6 mm×250 mm, 5 μm) column at 25 ℃. The mobile phase was consisted of acetonitrile and water including 20 mmol·L-1 ammonium acetate and 0.1% formic acid (85∶15) with a flow rate of 0.3 mL·min-1. The plasma samples were precipitated by acetonitrile. LC-MS/MS detection was made with an electrospray positive ionization and multiple reaction monitoring. RESULTS The calibration curves of each organophosphorus pesticide showed a good linearity in a range of concentration between 0.05-10 μg·mL-1. Lower limit of quantitation was 0.05 μg·mL-1 and the limits of detection were ranged from 0.1 to 5 ng·mL-1. The recoveries were between 93.23% and 107.5%. The intra- and inter- batch precisions were less than 10% and the stability was good. CONCLUSION The method is proved to be accurate, sensitive, simple and fast. It can be used to screen and determine the organophosphorus pesticides in patients, which can effectively support the diagnosis and efficacy evaluation of poisoned patients in clinical practice.
Key words:  plasma  organophosphorus pesticide  LC-MS/MS  determination