• 首页期刊简介编委会刊物订阅专栏专刊电子刊学术动态联系我们English
引用本文:昝珂,陆静娴,祝清岚,周颖,郑成.香丹注射液与乳酸钠林格注射液的配伍稳定性研究[J].中国现代应用药学,2021,38(20):2564-2567.
ZAN Ke,LU Jingxian,ZHU Qinglan,ZHOU Ying,ZHENG Cheng.Study on Compatible Stability of Xiangdan Injection and Sodium Lactate Ringer's Injection[J].Chin J Mod Appl Pharm(中国现代应用药学),2021,38(20):2564-2567.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 1562次   下载 735 本文二维码信息
码上扫一扫!
分享到: 微信 更多
香丹注射液与乳酸钠林格注射液的配伍稳定性研究
昝珂1, 陆静娴2, 祝清岚2, 周颖2, 郑成2
1.中国食品药品检定研究院, 北京 102629;2.浙江省食品药品检验研究院, 国家药品监督管理局中成药质量评价重点实验室, 杭州 310052
摘要:
目的 考察香丹注射液与乳酸钠林格注射液配伍的稳定性,为临床安全用药提供参考。方法 按临床用药配伍使用量,制备香丹注射液与乳酸钠林格注射液的配伍溶液,考察配伍溶液的外观、pH值、不溶性微粒、紫外光谱及丹参素钠、原儿茶醛、咖啡酸、紫草酸、丹酚酸B和丹酚酸A的多指标含量。结果 香丹注射液与乳酸钠林格注射液配伍6 h内,溶液性状、pH值、紫外光谱均无显著变化,不溶性微粒呈下降趋势,丹参素钠、原儿茶醛、咖啡酸和丹酚酸B的含量无显著性变化(<3%),紫草酸含量下降了17.41%,丹酚酸A的含量下降了78.64%。结论 香丹注射液与乳酸钠林格注射液在配伍6 h内部分有效成分含量下降,建议减少配伍或配伍后尽快输注,以提高输液的有效性与安全性。
关键词:  香丹注射液  乳酸钠林格注射液  配伍  稳定性
DOI:10.13748/j.cnki.issn1007-7693.2021.20.015
分类号:R917.101
基金项目:浙江省基础公益研究计划项目(LGF19H280001)
Study on Compatible Stability of Xiangdan Injection and Sodium Lactate Ringer's Injection
ZAN Ke1, LU Jingxian2, ZHU Qinglan2, ZHOU Ying2, ZHENG Cheng2
1.National Institutes for Food and Drug Control, Beijing 102629, China;2.Zhejiang Institute for Food and Drug Control, NMPA Key Laboratory of Quality Evaluation of Traditional Chinese Medicine(Traditional Chinese Patent Medicine), Hangzhou 310052, China
Abstract:
OBJECTIVE To investigate the compatible stability of Xiangdan injection and Sodium Lactate Ringer's injection, and to provide reference for clinical safe medication. METHODS According to the amount of clinical application, Xiangdan injection was prepared with Sodium Lactate Ringer's injection. The appearance of the compatibility of solution, pH value, insoluble particles, ultraviolet spectrum and the contents of the salvianolic acid sodium, protocatechuic aldehyde, caffeic acid, lithospermic acid, salvianolic acid B, salvianolic acid A were determined. RESULTS The solution properties, pH value, UV spectrum had no change and particulate matter had decreased slightly within 6 h after the compatibility of Sodium Lactate Ringer's injection, and the content of lithospermic acid, salvianolic acid A had decreased by 17.41% and 78.64% respectively within 6 h after the compatibility of Sodium Lactate Ringer's injection, while the other contents had no change(<3%). CONCLUSION The content of effective components decreased within 6 h after Xiangdan injection and Sodium Lactate Ringer's injection compatibility. It is suggested not to infuse or infuse as soon as possible after compatibility to improve transfusion safety and effectiveness.
Key words:  Xiangdan injection  Sodium Lactate Ringer's injection  compatibility  stability
扫一扫关注本刊微信