引用本文:林丽琴,彭彦,金朦娜,高丽琼,汪霞,王秀秀.2D-LC-Q-TOF-MS鉴定门冬氨酸钾镁注射液中的未知杂质[J].中国现代应用药学,2023,40(19):2721-2727.
LIN Liqin,PENG Yan,JIN Mengna,GAO Liqiong,WANG Xia,WANG Xiuxiu.Identification of the Unknown Impurity in Potassium Aspartate and Magnesium Aspartate Injection by 2D-LC-Q-TOF-MS[J].Chin J Mod Appl Pharm(中国现代应用药学),2023,40(19):2721-2727.
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 793次   下载 445 本文二维码信息
码上扫一扫!
分享到: 微信 更多
2D-LC-Q-TOF-MS鉴定门冬氨酸钾镁注射液中的未知杂质
林丽琴, 彭彦, 金朦娜, 高丽琼, 汪霞, 王秀秀
杭州市食品药品检验研究院, 杭州 310022
摘要:
目的 通过中心切割二维液相色谱-飞行时间质谱联用技术(2D-LC-Q-TOF-MS)分离,鉴定门冬氨酸钾镁注射液中的未知杂质。方法 采用Waters ACQUITY UPLC 2D超高效二维液相系统和Xevo G2-XS QTof-四极杆飞行时间质谱系统,一维液相色谱采用Agilent ZORBAX-NH2色谱柱,以0.05 mol·L-1磷酸二氢钾溶液-乙腈(37∶63)为流动相,流速为1.3 mL·min-1,检测波长为200 nm;二维液相色谱采用Waters ACQUITY UPLC HSS T3色谱柱,以0.1%甲酸(ESI+)/ 5 mmol·L-1甲酸铵(ESI-)为流动相A,以乙腈为流动相B,梯度洗脱;质谱采用电喷雾电离源(ESI),正负离子模式检测。结果 通过高分辨质量数和二级质谱碎片,结合UNIFI软件,推测得到了门冬氨酸钾镁注射液中的未知杂质的可能结构。结论 2D-LC-Q-TOF-MS可用于门冬氨酸钾镁注射液中杂质的在线定性鉴别,为门冬氨酸钾镁注射液的质量控制和工艺优化提供参考依据。
关键词:  门冬氨酸钾镁注射液  杂质  中心切割  液相色谱-质谱联用
DOI:10.13748/j.cnki.issn1007-7693.20222087
分类号:R927.11
基金项目:
Identification of the Unknown Impurity in Potassium Aspartate and Magnesium Aspartate Injection by 2D-LC-Q-TOF-MS
LIN Liqin, PENG Yan, JIN Mengna, GAO Liqiong, WANG Xia, WANG Xiuxiu
Hangzhou Institute for Food and Drug Control, Hangzhou 310022, China
Abstract:
OBJECTIVE To study the unknown impurity in potassium aspartate and magnesium aspartate injection by heart-cutting two-dimensional liquid chromatography coupled with Quadrupole time-of-flight mass spectrometry (2D-LC-Q-TOF-MS). METHODS The Waters ACQUITY UPLC 2D system and Xevo G2-XS QTof-MS system were used. One- dimensional chromatographic conditions were as listed. An Agilent ZORBAX-NH2 column was used, and potassium dihydrogen thophosphate(0.05 mol·L-1)-acetonitrile(37∶63) as the mobile phase, at a flow rate of 1.3 mL·min-1. The detection wavelength was set at 200 nm. Two-dimensional chromatographic conditions were as listed. A Waters ACQUITY UPLC HSS T3 column was used, and 0.1% formic acid solution(ESI+)/5 mmol·L-1 ammonium formate(ESI-) as the mobile phase A, and acetonitrile as the mobile phase B, in gradient mode. The mass spectrometry used an electro spray ionization source(ESI) for positive and negative ion mode detection. RESULTS Combined the high resolution mass, MS2 fragment ions and the UNIFI software, the possible structure of the unknown impurity in potassium aspartate and magnesium aspartate injection was infered. CONCLUSION The 2D-LC-Q-TOF-MS method can be used to identify impurities in potassium aspartate and magnesium aspartate injection, which provides reference for the improvement of quality control and process optimization of potassium aspartate and magnesium aspartate injection.
Key words:  potassium aspartate and magnesium aspartate injection  impurity  heart cutting  LC-MS